Description
The Wylex NMRS76206LA all metal consumer unit is fully compliant with Amendment 3 to BS 7671:2008. A twin RCD high integrity split load 2 + 7 + 6 fixed busbar configuration protecting two banks of four MCBs the unit is supplied with 100A switch isolator and 2 x 80A 30mA RCDs.
The NMRS76206LA high integrity consumer unit works by using three busbars instead of one. One busbar for each of the RCDs and one for the main switch. They are connected via fly leads such that the main switch is still used to isolate the entire board. Consequently, a High Integrity consumer unit allows you to protect all your mission critical circuits, such as smoke alarms, security system, fridge freezer etc. through the use of RCBOs independently.
The metal enclosure comes supplied with a full metal DIN rail and full complement of earth and neutral terminals along with circuit identification labels providing clear understanding of outgoing ways.
Features.
1 x 100 Amp DP Main switch controls the entire board and allows for up to 4 x RCBO’s or MCB’s circuits.
2 x 80 Amp 30mA RCD allowing form RCD circuits to be split around a building.
Max No of MCB’s or RCBO’s = 13.
Dual 80Amp 30mA RCD Protection.
Allows 100% RCD Protection.
Option for High Integrity with Individual RCBOs.
Allows for RCD Exemptions on MCBs.
Main Switch controls all circuits.
Almost unlimited combinations.
Second RCD for 2nd Group of Circuits.
Dimensions: H: 261mm x W: 438mm x D: 121mm (inc cover).
Technical Specification
All metal enclosure, no external plastic parts
Low Smoke & Fume paint
Non combustible cover blanks
Compact enclosure
Available in no miss terminal’ fixed busbar versions and flexible versions
Raised & removable DIN rail / busbar assembly
Cable entry knockouts on 5 sides, top, bottom, left, right and rear
Mains tails cable entry grommet / gland for supplementary insulation similar to Class II level of protection to mains tails
Up to 38 way units, all designs Main Switch, High Integrity, Split Load, Dual RCD l RoHS compliant in excess of UK standards
UKAS certified to BS EN 61439-3
Ean Code | 5013601108582 |
Range | Wylex NM Series |
Sensitivity | 30 mA |
Product | Consumer Unit w/ Main Switch + RCD |
Current Rating | 100A |
High Integrity | Yes |
Rcd Sensitivity | 30 mA |
Body Material | Steel |
Outgoing Ways | 15 Way |
Incomer Included | Y |
Incomer Current Rating | 80 A |
Rcd S Included | Y |